Johnson County’s own permit office approved 868 septic systems in 2025, and 824 of them were surface irrigation, the aerobic-and-spray design. That is 94.9 percent, from TCEQ’s report on systems installed by each authorized agent. Standard trench or bed systems were 30. Ten years earlier the county approved 356 systems, 290 of them spray. The Census Bureau puts the county at 218,048 people in July 2025, up from a 2020 base of 180,009.
Three cities also report septic approvals to TCEQ under Johnson County: Burleson (11 in 2025), Joshua (9) and Cleburne (none). TCEQ’s agent register lists a fourth, Fort Worth, for its city limits in the county; Fort Worth files its reports under Tarrant County. Everything else outside city limits goes to Johnson County Development Services, which acts as TCEQ’s designated representative. The county Order also reaches any town that signs an intergovernmental contract with the county.
The soil survey points the same way. NRCS’s Johnson County survey (TX251, September 2026 data, queried for this page) rates the main soil of map units covering 432,815 of 469,626 acres “Very limited” under its national septic absorption field rating, 92.2 percent, and no unit’s main soil rates “Not limited.” NRCS’s Texas version of that rating, used in this page’s soil card, weighs every soil in each unit and puts 72.9 percent of rated ground in the same class. Slow water movement is a fully limiting feature across 303,907 acres and depth to bedrock across 115,368. Half the county sits in the Grand Prairie, about 30 percent in the East Cross Timbers and 19 percent in the northern Blackland Prairie. The largest unit, the Aledo-Bolar association, covers 70,482 acres; NRCS puts Aledo’s limestone 9 to 20 inches down. Heiden clay, next at 52,543 acres, is very slowly permeable with high shrink-swell potential.
The county Order, adopted August 27, 2018 and approved by TCEQ on October 3, 2018, sets these local rules:
A permit, application and inspection are required “regardless of the size of the tract of land,” so the 10-acre exemption does not apply in the county’s jurisdiction.
New single-family lots need one acre on public water and two on a private well.
An owner cannot install a system without an installer license.
Site evaluations are limited to “a registered professional engineer or registered professional sanitarian holding a valid TCEQ site evaluator license,” and every design must come from an engineer or sanitarian.
The county inspects each new system before it is covered, and the applicant or installer must be there.
The 2025 subdivision rules add a 150-foot street frontage minimum and allow one house per septic system, with two acres for a duplex and an acre more for each added unit.
Development Services lists $375 for a conventional, evapotranspiration-bed or low-pressure-dosing permit and $475 for an aerobic one, effective October 23, 2023. A re-inspection or redesign is $210 and a failed inspection $100. The Order adds the $10 state fee per permit, and an authorization to construct is good for one year. Applications go by email to development@johnsoncountytx.org. Running costs for the spray systems most owners here end up with are in the aerobic system cost guide; the county’s aerobic affidavit requires a two-year service policy, after which a single-family owner may contract or do the work personally, as the maintenance contract guide explains.
Homes in the Johnson County part of the Joe Pool Lake and Village Creek-Lake Arlington watersheds can apply to the Trinity River Authority for up to $8,000 toward a septic repair or replacement. TRA says its last funds ran out May 5, 2025 and its next cycle runs September 2026 to August 2029.
Johnson County Development Services, Johnson County Annex, 2 N Mill St, Suite 305, Cleburne, (817) 556-6380, Monday to Friday 8 a.m. to 11:45 a.m. and 1 to 4:45 p.m. per the county’s site (TCEQ’s register lists 8 to noon and 1 to 5). Burleson, Joshua, Cleburne and Fort Worth issue septic approvals inside their own city limits, per TCEQ’s agent register; how the state splits septic permitting is in the Texas permit authority guide.
Providers
Johnson County septic companies, verified first.
Each listing shows how it matched TCEQ records, with its license number and phone. Anything we could not match is labeled as such, never badged.
No matching septic companies verified in Johnson County yet.
We only list providers we can check against TCEQ records — no padding, no scraped listings. Clear the filter to see every verified Johnson County pro, or tell us what you need and we’ll route it to pros who serve the area.
iOrganic order is verified-first then A–Z and is never sold; featured slots, when they exist, are labeled. Methodology
Get quotes from Johnson County septic companies.
Pumping, an inspection, or fixing a septic system: tell us once and up to 3 verified Johnson County septic companies get it. Free, no spam, delete anytime.
New installs and major repairs need a permit from the local authorized agent — usually the county, sometimes a city — and the rules that bind are the local ones.
This county’s full guide is still in production — the authority contact shown here is the official source in the meantime.
Four things decide what you can build and what it costs: zoning, environmental protections, power for aerobic systems, and the ground itself. We publish each one only where we have checked it — and say so plainly where the answer is “same as the rest of Texas”.
Zoning & land use
Johnson County issues the septic permit for the unincorporated county. It holds that job only because the commissioners court adopted an on-site sewage facility order and TCEQ approved it (Health and Safety Code § 366.031), and § 366.032(b) makes that order prevail wherever it is stricter than 30 TAC Chapter 285. Ask the office for its current order — Texas counties have no general zoning power, so the order, not zoning, is where a local siting rule sits.
Nothing in Johnson County changes this.
Texas adds a separate approval path over the Edwards Aquifer recharge, transition and contributing zones, where TCEQ requires an Edwards Aquifer Protection Plan under 30 TAC Chapter 213. Elsewhere the Chapter 285 rules stand on their own.
The dominant constraint here is clayey subsoil that water moves through too slowly (56.3% of rated soils), followed by bedrock close to the surface (25.5%). NRCS rates 72.9% of rated ground very limited for a standard soil absorption field, 32.3% for subsurface drip and 15.0% for surface application with disinfection. Where a conventional field will not pass, surface application is usually the route that does.
Get free quotes from verified Johnson County septic companies.
Pumping, an inspection, or help fixing a septic system: tell us once and we send it to up to 3 verified septic companies. Free, no spam, delete your request anytime.
Secure form. Sent over an encrypted connection to up to 3 verified septic companies. Never sold to data brokers, and you can have your request deleted anytime.