Sizing rules are set state by state, and they disagree. There is no national answer to size a tank against.
Every rule here sizes on bedrooms, not on how many people live in the house. Bedrooms do not change when the family does.
Every row of the design-flow table carries a floor-area ceiling, so square footage can move a house up a size on its own.
Pick a state and a bedroom count. The answer appears here with the rule it comes from, the rule’s own publication date, and the working where the figure is arithmetic rather than a printed row.
If nothing appears, JavaScript is switched off. The four-state comparison in the septic tank size chart is a plain table and needs none.
Answer two questions and get the minimum tank your state’s own rule requires, with the rule cited next to the number and the arithmetic shown. Eight state rules, read from the rule text. Where a rule is ambiguous, this tool quotes it and stops.
Two questions are always asked and two more are asked only where a rule reads them.
Which state the property is in comes first, because sizing rules are set state by state and they disagree. There is no national answer to size a tank against.
Bedrooms come second. Every rule here sizes on bedrooms, not on how many people live in the house, because bedrooms do not change when the family does.
Floor area is read by one rule in the set, where every row of the design-flow table carries a floor-area ceiling and square footage can move a house up a size on its own. A fixture question is read by two: one names water-saving devices without defining them, the other names a garbage disposal or a sewage ejector and requires half again the capacity when either is present. On the states whose rules read neither, both inputs are switched off in place and say why.
It is a minimum liquid capacity, which is not the number on the side of the tank. Every rule here sets a liquid capacity: the working volume below the liquid line. The space above it is freeboard and does not count toward the figure. It is also not a permit and not a quote. The office that reviews your plan has the last word, and it can require more.
Every figure was read from the rule that sets it, not from a chart, a supplier catalog or another website. The rule and its own publication date sit next to the answer, and the rule text is one click away. Where the answer is our arithmetic on a formula the rule prints, the result says so and shows each step. The full comparison and the reasoning behind it live in the septic tank size chart.
A drain field is sized on soil, not on bedrooms: the design flow divided by the hydraulic loading rate for the soil the field sits in. Several of these states publish those loading rates as scanned tables we have not read, and a loading rate we have not read is one we will not print. So this tool sizes the tank and stops. Ask your permitting authority for the loading rate assigned to your soil class; it is the one input that decides the field.
Six of these eight rules publish a bedrooms-to-gallons table you can read straight off. Two publish a daily flow first, then a formula that turns that flow into gallons. One of the six switches to a formula of its own above five bedrooms. That structural split is why a chart copied from one state is wrong in the next, and it is the reason this tool asks which state before it asks anything else. Every rule below was read in the text the state publishes.
| State | What the rule sizes on | Rule |
|---|---|---|
| Texas | A design flow in gallons per day, set by bedrooms and floor area, then a capacity formula run on that flow. | 30 TAC 285.91(3) Table III and 285.91(2) Table II |
| Ohio | Bedrooms alone, read straight off a four-item list in the rule. | OAC 3701-29-12(C)(1) |
| Pennsylvania | A daily flow figure, then a two-band capacity formula run on that flow. | 25 Pa. Code 73.31(a) |
| Washington | Bedrooms alone, from a two-row table. | WAC 246-272A-0232, Table VII |
| Minnesota | Bedrooms alone, in four bands, with a 50 percent uplift for two named fixtures. | Minn. R. 7080.1930, subp. 1, Table V |
| Tennessee | Bedrooms alone, from a three-row table with a footnote for larger houses. | Tenn. Comp. R. & Regs. 0400-48-01-.08(1) |
| Alabama | Bedrooms alone, from a two-row table with an add-per-bedroom footnote. | Ala. Admin. Code r. 420-3-1-.27(1)(g) and Appendix A, Table 9 |
| Missouri | Bedrooms alone up to five, then a flow formula the rule sends larger houses to. | 19 CSR 20-3.060(4)(B)16 and Table 4 |
Each row carries the agency that adopted the rule and the rule’s own publication date on the page, next to the citation. Those are two different dates and this page keeps them apart.
One provision in this set is genuinely ambiguous about houses of six bedrooms and more. Two readings of the same sentence give two different tanks, and the rule does not say which is meant. The calculator prints the sentence and stops. Guessing would look like an answer and be worth less than none.
A legal minimum is a floor, not a recommendation. Designers routinely go up a size for a house with a garbage disposal, a long pump run, or a lot with no room to rebuild a field later. If your installer proposes more than the minimum, ask why, and expect an answer about your site rather than about the rule.
| State | What the rule sizes on | Rule |
|---|---|---|
| Texas | A design flow in gallons per day, set by bedrooms and floor area, then a capacity formula run on that flow. | 30 TAC 285.91(3) Table III and 285.91(2) Table II Texas Commission on Environmental Quality, TCEQ adopted rule text, Rule Project 2021-030-285-CE, effective July 6, 2023 |
| Ohio | Bedrooms alone, read straight off a four-item list in the rule. | OAC 3701-29-12(C)(1) Ohio Department of Health, rule effective January 1, 2015 |
| Pennsylvania | A daily flow figure, then a two-band capacity formula run on that flow. | 25 Pa. Code 73.31(a) Pennsylvania Department of Environmental Protection, section last amended effective November 8, 1997, current on the Pennsylvania Code through 56 Pa.B. 4026 |
| Washington | Bedrooms alone, from a two-row table. | WAC 246-272A-0232, Table VII Washington State Department of Health, section effective July 1, 2007, amended effective April 1, 2025 |
| Minnesota | Bedrooms alone, in four bands, with a 50 percent uplift for two named fixtures. | Minn. R. 7080.1930, subp. 1, Table V Minnesota Pollution Control Agency, published electronically October 10, 2013 (history 32 SR 1347; 35 SR 1353) |
| Tennessee | Bedrooms alone, from a three-row table with a footnote for larger houses. | Tenn. Comp. R. & Regs. 0400-48-01-.08(1) Tennessee Department of Environment and Conservation, Division of Water Resources, rule filed June 20, 2013, effective September 18, 2013; April 2014 revision of the chapter |
| Alabama | Bedrooms alone, from a two-row table with an add-per-bedroom footnote. | Ala. Admin. Code r. 420-3-1-.27(1)(g) and Appendix A, Table 9 Alabama Department of Public Health, chapter filed January 19, 2017, effective March 6, 2017 |
| Missouri | Bedrooms alone up to five, then a flow formula the rule sends larger houses to. | 19 CSR 20-3.060(4)(B)16 and Table 4 Missouri Department of Health and Senior Services, rule filed April 17, 1995, effective December 30, 1995; Code of State Regulations compilation dated September 30, 2020 |